İçeriğe geç
Çukurova ÜniversitesiTürkoloji Araştırmaları MerkeziBilimsel bilgiye açık erişim
Türkoloji Veri Arşivi

Reliability of antibody tests for COVID-19 diagnosis

Yayımlandığı dergi: Marmara Medical Journal, Vol. 36 No. 1 · Akıllı makale kaydı, kaynakça araçları ve ilişkili çalışmalar.

← Listeye dön
Arşiv kaydı 23460 Dergipark Crossref DOI doğrulandı Açık erişim doğrulandı

Yayımlandığı dergiMarmara Medical Journal, Vol. 36 No. 1

Nilay Coplu ORCIDCetin Kılınc ORCIDAysegul Gozalan ORCIDBusra Calısır ORCIDCemile Sonmez ORCIDMustafa Muhammet Gul ORCIDZeynep Aygun Ahlatcıoglu ORCID

Yayın yılı
2022
Dergi / yayın
Marmara Medical Journal, Vol. 36 No. 1
DOI
10.5472/marumj.1245068
Atıf sayısı
0 Crossref
Kaynakça kaydı
23

Özet

Objective: The reverse transcription–polymerase chain reaction test (RT-PCR) is the gold standard for the diagnosis of coronavirusdisease 2019 (COVID-19), and antibody tests are useful as supplemental tools for diagnosis, for measuring the population’s immunitylevels, and for checking infection in asymptomatic contacts. This study aimed to evaluate the reliability of five commercial antibodydetection test kits.Materials and Methods: The reliability of the Colloidal Gold COVID-19 IgG/IgM Rapid Test Kit, Antibody Rapid Test Hotgen,Beijing Hotgen Biotech Co., Ltd., China), Abbott Chemiluminescent Microparticle Immunoassay (Illinois, USA), RocheElectrochemiluminescence Immunoassay (Roche Diagnostics, Switzerland), Siemens Chemiluminescence (Munich, Germany), andEuroimmun ELISA (Lübeck, Germany) for COVID-19 diagnosis was studied. The antibody-negative group included 50 sera from2018, and the antibody-positive group included 98 patients with positive RT-PCR results from whom blood samples had been collected3–9 weeks after hospital discharge. Statistical analysis was performed using SPSS version 23.0 (IBM Corporation, Armonk, NY, USA).The antibody tests’ validity and intra-assay reproducibility were examined, and the Cohen’s kappa coefficients were obtained. Thedisease prevalence was pegged at 10%.Results: The antibody tests’ sensitivity (69.12–72.46%) and positive predictive values (42.44–100.0%) were low, and their specificity(89.58–100%) and negative predictive values (96.31–97.03%) were high. Their accuracy rates varied from 87.54% to 97.25%, and theirintra-assay coefficients of variation varied from 1% to 10%.Conclusion: The agreement between the results of the antibody detection test kits was higher when the kits were classified according tothe targeted antigens. The time of blood sample collection, targeted antigens, and antibody types affected the results. Serological testswere found to be useful, and the commercial kits were found to be largely reliable, although, some parameters need to be improved.

Kayıt güvenilirlik pasaportu

Kaynağı ve değişiklikleri görünen üstveri

Bu kart akademik kalite puanı vermez; bibliyografik alanların nereden geldiğini, ne zaman denetlendiğini ve onaylı düzeltmeleri gösterir.

Yerel kayıt
ÇÜTAM 23460
Arşive eklenme
15.07.2026 12:15
Üstveri sağlayıcı
Dergipark
Kaynak bağlantısı
Otomatik denetim bekliyor
DOI durumu
Crossref kaydıyla eşleşti
Açık erişim
Erişim bağlantısı doğrulandı
Yayıncı
Marmara University
Son üstveri denetimi
15.07.2026 12:15
Değişiklik ilişkisi
Bildirilen düzeltme/geri çekme ilişkisi yok

Kaynakçaya ekle

Zotero, EndNote ve diğer kaynakça yöneticilerine uygun biçimi indirin.

BibTeXRISCSL JSON

Atıf sayıları ve DOI kaynakça bağları Crossref üstverisinden; yerel ilişkiler Türkoloji arşivindeki başlık ve yazar yakınlığından oluşturulur.